XL BCL3 BA

Break Apart Probe

Order Number
D-5128-100-OG
Package Size
100 µl (10 Tests)
Labels
  
Chromosome
19
Regulatory Status
IVDR

IVDR Certification

This probe is IVDR-certified in compliance with the Regulation (EU) 2017/746 for in vitro diagnostic medical devices (IVDR).

MetaSystems Probes has already certified a wide range of FISH probes, according to IVDR.

Please use the switch to change to the IVDD product.

IVDDIVDRDiscover all IVDR-certified productsDownload Instructions For Use (IFU)

Until further notice, we will continue to provide IVDD products in various countries.

As part of our phased rollout, the IVDR-certified probes are now available in Australia, Austria, Belgium, Croatia, Cyprus, Czech Republic, Estonia, France, Germany, Iceland, Italy, Kuwait, Lebanon, Liechtenstein, Luxembourg, Malta, Netherlands, New Zealand, Poland, Slovakia, Slovenia, South Africa, and Switzerland, with the list of countries continuously expanding.

Intended Purpose

The XL BCL3 BA break-apart probe is a qualitative, non-automated test for the detection of BCL3-rearrangements at 19q13.3 by fluorescence in situ hybridization (FISH). The product is intended as a diagnostic aid and assists in disease monitoring. The test population consists of patients with confirmed or suspected chronic lymphocytic leukemia (CLL) and non-Hodgkin-lymphomas (NHL). Hybridization is to be performed on methanol/acetic-acid fixed cells derived from bone marrow or peripheral blood for CLL and on methanol/acetic-acid fixed cells derived from involved lymph node, involved bone marrow or other involved tissue for NHL.

Product Description

XL BCL3 BA

The XL BCL3 BA break-apart probe consists of an orange-labeled probe hybridizing proximal to the BCL3 gene region at 19q13.3 and a green-labeled probe hybridizing distal to the BCL3 gene region at 19q13.3.

Probe maps for selected products have been updated. These updates ensure a consistent presentation of all gaps larger than 10 kb including adjustments to markers, genes, and related elements. This update does not affect the device characteristics or product composition. Please refer to the list to find out which products now include updated probe maps.

Probe map details are based on UCSC Genome Browser GRCh37/hg19, with map components not to scale.

Need assistance or a quote?

Images

XL BCL3 BA

XL BCL3 BA hybridized to bone marrow cells. One aberrant cell with split signal is shown, indicating a break in the BCL3 locus.

Need assistance or a quote?

Expected Patterns

Expected Pattern 1

Normal Cell:
Two green-orange colocalization/fusion signals (2GO).

Expected Pattern 2

Aberrant Cell (typical results):
One green-orange colocalization/fusion signal (1GO), one separate green (1G) and orange (1O) signal each resulting from a chromosome break in the respective locus.

Need assistance or a quote?

Downloads

News